Sheathed thermocouple is used as measuring element for furnace wall thermocouple which forms cable condition. Thermal connection point is fixed on stainless steel with different curves. It is used to surface temperature measurement in furnace pipe wall, furnace wall and other cylinder surfaces.
Normal Pressure
R≥5D
| Type | Graduation | Temperature range (°C) | TRT | Measurement Type | Specification | |
|---|---|---|---|---|---|---|
| L | L1 | |||||
| WRNK-191M, WRNK2-191M, WRNT-11, WRNT2-11 | K | 0 ~ 800 | ≤2.5 | Insulation type | 1000, 2000, 3000, 4000, 5000, 6000, 8000, 10000, 15000 20000, 25000 | 1000, 2000, 3000, 4000, 5000, 6000, 8000, 10000, 15000 20000, 25000 |
| WREK-191M, WREK2-191M, WREK-11, WREK2-11 | E | 0 ~ 600 | ||||